检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张培铭[1] 董纪清[1] 陈丽辉[1] 许志红[1]
机构地区:[1]福州大学电气系,350002
出 处:《电工技术杂志》2003年第1期19-20,共2页Electrotechnical Journal
摘 要:介绍了将可控电力电子器件与直流接触器相结合而形成的智能型直流接触器的原理及结构This paper develops the principle and structure of intelligent DC contactor,with the combination of the technique from power electronics device and traditional DC contactor The apparatus close and break the circuit by power electronics device On the other times,DC contactor work The contacts of intelligent DC contactor realize the no arc closed and broken control So the electrical endurance of intelligent DC contactor has been improved greatly The performance of DC contactor has been promoted greatly The control function of DC contactor has been enhanced and saved siler and other material