作 者:郑进福 周志刚[1] 赵加宁[1] 刘志君 王晋达 王尧 李振元 ZHENG Jinfu;ZHOU Zhigang;ZHAO Jianing;LIU Zhijun;WANG Jinda;WANG Yao;LI Zhenyuan(Harbin Institute of Technology,Harbin 150090,Heilongjiang,China;Jilin Electric Power Co.,Ltd of State Grid,Changchun 130021,Jilin,China)
机构地区:[1]哈尔滨工业大学,黑龙江哈尔滨150090 [2]国网吉林省电力有限公司,吉林长春130021
出 处:《建筑科学》2019年第6期122-127,共6页Building Science
基 金:国家科技支撑计划课题(项目编号2015BAA01B01);黑龙江省自然科学基金关键课题(ZD2016010)
摘 要:供热系统动态热特性研究不仅可以优化供热系统运行调节,对于提高新能源供热的安全性、经济性、环保性也具有重要意义。本文利用节点法对供热系统的动态热特性进行研究,在快速且大幅度的热源供水温度变化情况下,利用节点法模拟距离热源不同远近的换热站的供水温度,分析供热管网的动态热特性。结果表明:每个换热站的总温降与距离热源的远近成正比,但是每单位长度的温降与距离热源的远近没有必然关系,主要与热源到换热站的管道流量(直径)和管长有关;同时分析节点法对不同温度变化阶段的模拟精度;节点法在快速且大幅度温度变化下的平均误差和标准差分别为0.46℃和1.18℃;最后通过定义动态响应时间分析流体在管网中的延迟时间,结果显示利用节点法计算得到的动态响应时间相对误差分别为5.8%和5.74%。所以节点法对于管网热动态特性研究的精度可以满足实际工程的需要。The research on the dynamic thermal characteristics of district heating system can not only optimize the regulation of district heating system,but also have important significance for improving the security,economics and environment of new energy heating.In this paper,the dynamic thermal characteristics of district heating system were analyzed with an emphasis on temperature distribution of the network.Therefore,a modeling approach named node method was applied to simulate the temperature distribution at stages with large and quick temperature change.Moreover,the node method was validated by applying it to a real district heating network at different stages of temperature change and comparing with measurements.Results showed that the supply temperature of each substation was proportional to the distance from the heat source,but its temperature decrease per unit of length was irrelevant with the distance from the heat source.Such temperature decrease needed to consider the impact of the flow and length of pipe synthetically.Also,the comparisons disclose that the average error and standard deviation were 0.46℃and 1.18℃,respectively.Finally,by defining the dynamic response time,the delay time of the fluid in the pipe network was analyzed.Results showed that the relative error of the dynamic response time calculated with the node method was 5.8%and 5.74%,respectively.Therefore,the node method was accurate enough to satisfy the requirements of practical engineering in the study of thermal dynamic characteristics of pipe network.
关 键 词:集中供热系统 动态温度模拟 节点法 动态响应时间
分 类 号:TU833.1[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3