摘  要:闸门的应力检测分析是大坝安全检查的重要内容。通过对西洱河流域大坝闸门的现场检测,探索了一套较为可靠实用的闸门安检方案。分析了门叶各构件在全闭档水和启闭运动时的应力状况,对于闸门长期存在的病害提出了较为合理的成因解释,进而给出了闸门整体性能和运行现状的评价结论以及治理建议。The stress testing and analysis of floodreleasing gate is an important to the dam safety inspection. On the basis of spot testing on the dam and gates on the Xi'er River, a reliable and practical method for the gate safety check is gained. The stress conditions of gate parts are analyzed with the conditions of hydrostatics or movement, causes of the gate disease are explained with reasons. The integral performances and operation conditions of gate are assessed and some maintaining suggestions are propound.