检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]同济大学土木工程防灾国家重点实验室,上海200092
出 处:《力学季刊》2003年第1期75-80,共6页Chinese Quarterly of Mechanics
基 金:国家自然科学基金(59823002)
摘 要:本文籍振动台模型试验,研究了SSI体系的合成模态阻尼比问题。文中首先阐明了在SSI体系直接动力分析中应采用合成模态阻尼比的观点,研究了合成模态阻尼比的实测确定方法。并在不同工况下,通过对模型不同部位测点的传递函数、基本频率、基本合成模态阻尼比等实测数据考察,验证了SSI体系合成模态的存在性、合成模态阻尼比与相同应变下不考虑相互作用的单纯地基土体或刚性地基结构阻尼比的差异性及其在递增动力作用下的变化规律。Based on the shaking table tests, the composite modal damping ratio of a soil-structure interaction system was studied by using system-identification method. Firstly, the composite modal damping ratio should be adopted in dynamic analysis of SSI system, and then the method how to estimate the composite modal damping ratio of SSI system was illustrated. Finally, throughout the experimental investigations of the transfer functions, the natural frequency and the damping ratio at different position of the system, the existence of composite modal of SSI system was proued, and there is a large difference between the composite modal damping ratio of SSI system and the modal damping ratio of fixed-base structure or one of soil without SSI effect. It also shows that the composite modal damping ratio varies with increasing simulated earthquake excitations.