氧碘化学激光器谐振腔腔镜失调测量与研究  被引量:13

Measure and research of mirrors disalignment for COIL resonator

在线阅读下载全文

作  者:刘岩[1] 金玉奇[1] 桑凤亭[1] 孙以珠[1] 刘嵚[1] 张治国[1] 

机构地区:[1]中国科学院大连化学物理研究所,辽宁大连116023

出  处:《强激光与粒子束》2003年第3期221-224,共4页High Power Laser and Particle Beams

基  金:国家863计划项目资助课题

摘  要: 为保证氧碘化学激光器谐振腔的腔镜失调测量结果的可靠性和准确性,建立了使用自准直仪间接测量腔镜失调的方法。测量结果表明,热辐射是引起腔镜失调并造成光束漂移的主要原因,通过采取措施,可以使腔镜失调明显减小。同时证明了该测量方法是可靠的、合理的。To insure reliable and accurate measurement results of mirror angular displacement for COIL resonator, indirect measurement was found using electronic autocollimator. Measurement results show that thermal radiation is main reason of mirror angular displacement and results in the beam spot drift for COIL. Adopting measures, the mirror angular displacement and the beam spot drift are obviously reduced. Experiments verify that the measurement method is reasonable and reliable.

关 键 词:谐振腔 腔镜失调 测量 氧碘化学激光器 腔镜偏移 光束漂移 