检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:笪耀东[1] 车得福[1] 庄正宁[1] 刘卫东 方胜
机构地区:[1]西安交通大学锅炉研究所,西安710049 [2]三北拉法克锅炉有限公司,河北张家口075000
出 处:《工业锅炉》2003年第1期12-15,34,共5页Industrial Boilers
摘 要:针对冷凝式燃气锅炉,利用加湿热空气模拟燃气锅炉尾部烟气,通过实验研究了不凝性气体占多数时的水蒸气冷凝换热,研究了不同水蒸气分压比(3%20%)、不同温度下(100200℃),加湿空气的冷凝换热特性。实验表明,不凝性气体(空气)占多数时,其对流冷凝复合换热系数可以达到无冷凝时干空气对流换热系数的1.53倍。复合换热系数的影响因素主要有水蒸气分压力pv、Re、Pr以及壁面温度Tw和混合气体主流温度Tg,在此基础上建立一个新的准则数Ln并拟合了冷凝换热Nu数的准则关系式。Condensation heat transfer characterization of a single-row condensing heat exchanger was investigated experimentally by using vapor-air mixture to simulate flue gas of a natural gas boiler. The experiments were conducted at different vapor volumetric concentrations (3%~20%) and a wide range of the mixture temperature (100~200℃). The forced convection-condensation heat transfer coefficient is 0.5~2 times more than that of the forced convection without condensation. Based on the experimental data, an empirical correlation of condensation heat transfer was obtained with a new dimensionless number Ln.
关 键 词:高水分烟气 对流冷凝换热 冷凝式燃气锅炉 准则关系系
分 类 号:TK229.8[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.225.92.18