125MW机组凝结水系统控制技术的改进  被引量:3

The Improvements of Condense Water System's Control Technique for 125MW Thermal Power Unit

在线阅读下载全文

作  者:吕剑虹[1] 陈来九[1] 石江陵 薛文顺 杨榕 

机构地区:[1]东南大学,南京210096 [2]南京热电厂,南京210055

出  处:《动力工程》2003年第2期2313-2316,共4页Power Engineering

基  金:国家自然科学基金 (5 0 0 760 0 8) ;江苏省青年科技基金 (BQ2 0 0 0 0 0 2 ) ;国家教委优秀青年教师基金 (教技司2 0 0 0 (65 )

摘  要:针对南京热电厂 6号机组 (1 2 5 MW)的凝结水系统 ,将凝结水泵的定速运行改造为变频调速 ,并采用模糊控制技术控制凝泵转速和补水门开度 ,以便在稳定或变负荷情况下维持除氧器水位和凝汽器水位。实际运行表明 ,该控制系统不仅具有优良的控制品质 ,而且由于凝泵采用了变频调速 ,具有非常明显的节能效果。图 2参For the condense water system of No.6 unit (125MW) in Nanjing Thermal Electrical Power Plant, this paper firstly uses transducers to regulating the speed of condense water pumps, then the fuzzy logic control technique is employed to maintain the deaerator's and condenser's levels. The practical running results show that the fuzzy control system not only had good performance, but also obtained clearly the effect of decreasing the power consumption of condense water pump because of the frequency regulating speed. Figs 2 and refs 6.

关 键 词:除氧器 凝汽器 凝结水泵 水位 模糊控制 变频调速 

分 类 号:TK264.1[动力工程及工程热物理—动力机械及工程]

 