摘 要:5MW低功率堆(5MW LPR)控制保护系统包括:反应堆核测量系统、反应堆保护系统,反应堆控制系统和主控制室等。本堆采用了国际或国内的标准结构形式,元器件和线路的选取注重可靠性和先进性,主要系统靠近标准化,在满足安全的条件下考虑了经济性和可用性。主控制室设计考虑了人因工程的要求,保证了反应堆运行环境等要求。The control and protection system for 5MW LPR are compri-sed of reactor nuclear measurment subsystem,reactor protectionsubsystem, reactor control subsystem and main control room su-bsystem.International and national standards have been sdoptedin its structure and form,and reliability and technique advanceprevail in element,device and circuit choice.The standardiztion,economization and usability are also considered under the condi-tion of meeting safety requirements.Human engineeering hasbeen introduced for the main control room design,so that a pro-per operational envirement is achieved.