Chemiluminescence Sensor for the Determination of Hydroxylamine by Electrostatically Immobilizing Luminol and Periodate  被引量:1

Chemiluminescence Sensor for the Determination of Hydroxylamine by Electrostatically Immobilizing Luminol and Periodate

在线阅读下载全文

作  者:ZHANG Si chun ZHOU Guo jun JU Huang xian 

机构地区:[1]Department of Chemistry,Institute of Analytical Science,State Key Laboratory of Coordination Chemistry,Nanjing University,Nanjing 210093,P.R.China

出  处:《Chemical Research in Chinese Universities》2003年第2期155-159,共5页高等学校化学研究(英文版)

基  金:Supported by the National Natural Science Foundation of China(No.2 9975 0 13,9835 110 )

摘  要:A novel chemiluminescence(CL) sensor, which can be used for hydroxylamine determination in combination with flow injection analysis, was developed by electrostatically immobilizing luminol and periodate on anion exchange resin respectively. Hydroxylamine was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The response of the sensor to hydroxylamine was linear in the concentration range of 8.0×10^(-8)-2.0×10^(-6)mol/L with a detection limit of 4.0×10^(-8)mol/L hydroxylamine(3σ).The relative standard deviation(RSD) was 2.0% for 9 repetitive determinations at a hydroxylamine concentration of 5.0×10^(-7) mol/L. The sensor could be reused for over 400 times with a good reproducibility and was used to determine hydroxylamine in wastewater.A novel chemiluminescence(CL) sensor, which can be used for hydroxylamine determination in combination with flow injection analysis, was developed by electrostatically immobilizing luminol and periodate on anion exchange resin respectively. Hydroxylamine was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The response of the sensor to hydroxylamine was linear in the concentration range of 8.0×10^(-8)-2.0×10^(-6)mol/L with a detection limit of 4.0×10^(-8)mol/L hydroxylamine(3σ).The relative standard deviation(RSD) was 2.0% for 9 repetitive determinations at a hydroxylamine concentration of 5.0×10^(-7) mol/L. The sensor could be reused for over 400 times with a good reproducibility and was used to determine hydroxylamine in wastewater.

关 键 词:Chemical sensor CHEMILUMINESCENCE LUMINOL PERIODATE HYDROXYLAMINE 

分 类 号:O657.1[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象