摘  要:利用MCNP程序研究了充气电离室的探测性能,计算了探测器内工作气体和电极片在射线探测中各自的作用,得到该电离室的探测效率。然后计算不同偏角入射时探测器的信号输出值,并给出计算的探测灵敏度。计算结果表明,高压充气电离室探测60Co源γ射线也可达到高的探测效率和灵敏度。In this paper, the MCNP code is used to study the detection performances of a gas ionchamber. Firstly, the interaction of working gas and electrode plane to γ rayis calculated, and then the detection efficiency is obtained. Then output signal values of a simulation detactor under different angle of incident ray, as weel as detection sensitivity, are given too. According to the calculating results of MCNP code, high pressure gas ionchamber can reach high detection efficiency and sensitivity to 60Co γray.