670t/h锅炉稳燃的改进措施及其效果  

Measures for Promoting the Stable Combustion in a 670t/h Boiler and Their Effectiveness

在线阅读下载全文

作  者:肖汉才[1] 何小耐 

机构地区:[1]长沙电力学院动力工程系,湖南长沙410077 [2]新余电厂,江西新余336500

出  处:《热能动力工程》2003年第3期313-314,共2页Journal of Engineering for Thermal Energy and Power

摘  要:论述 2 0 0MW机组配套 6 70t/h锅炉 ,常会遇到燃煤灰份高、调峰负荷低等严重影响锅炉稳定燃烧 ,甚至导致熄火或大量投油助燃的情况。通过选用双置浓淡分离燃烧器等一系列改进措施后 ,既能保持锅炉稳燃提高效率 。The 670t/h boiler of a 200MW power plant often has to cope with a variety of unfavorable conditions, which can seriously impair the stable combustion of the boiler, and even cause a flame failure or entail the necessity to go for a copious oil assisted combustion. Such conditions include high ash content of coal and low peak shaving load, etc. A series of measures were taken to improve the situation, which resulted in a stable combustion, higher efficiency and reduced oil consumption for the boiler, contributing to an increase in economic benefits.

关 键 词:燃煤高灰份 调峰低负荷 叉式煤粉喷嘴 双置浓谈分离 稳燃 锅炉 