脉冲电解处理餐饮废水的试验研究  被引量:14

Study on the Electrolysis Treatment of Restaurant Wastewater with Pulse Curr ent

在线阅读下载全文

作  者:宋卫锋[1] 朱又春[1] 林美强[1] 

机构地区:[1]广东工业大学环境科学与工程学院,广东广州510090

出  处:《四川环境》2003年第3期1-3,7,共4页Sichuan Environment

基  金:广东工业大学青年基金资助课题(0 2 30 0 1)

摘  要:脉冲电解是废水电解处理技术发展的一个重要方向。本文用改装的直流、脉冲两用电源对餐饮废水做了对比处理研究。试验结果表明 ,脉冲电解的处理效果优于直流电解 ,在CODCr的去除率相近的情况下 ,电耗可降低 5 5 %。当脉冲频率为1 67KHz,水力停留时间为 2 9min,电流为 50mA时 ,电耗为 0 2 2 2KWh/m3 ,CODCr的去除率可以达到 83 1 %。The pulse electrolysis is one of the impor ta nt developing trends of electrolysis wastewater treatment technology The modif ied direct and pulse current supplier is employed to treat the restaurant waste water in this paper The results show that the effect of pulse current is bette r than that of direct current When the COD Cr removal ratio is simila r, the power consumption can be saved by 5% On the condition that the frequenc y is 1 67KHz, the HRT is 29min and the current is 50mA, 0 222KWh/m 3 of power con sumption and 83 1% of COD Cr removal ratio can be obtained

关 键 词:脉冲 电解 镊饮废水 

分 类 号:X703.1[环境科学与工程—环境工程]

 