检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王佳[1]
机构地区:[1]北京建筑工程学院,北京100044
出 处:《电力学报》2003年第1期5-7,共3页Journal of Electric Power
基 金:北京自然科学基金资助项目 (3 942 0 0 7)
摘 要:介绍一种含铁心元件网络的暂态计算方法。在这一方法中 ,首先建立铁磁元件励磁支路的模型 ,即以光滑连续的公式来描述非线性励磁特性 ,取代传统的分段线性化模型 ,然后再给出含铁心元件网络的暂态算法。该算法从非线性励磁支路的求解出发 ,通过对剩余线性网络的暂态计算 ,得到整个网络的全解。应用该算法 。This paper presents an efficient method for transient calculation of power system.A new model is developed to represent the magnetzing characteristics, in which the magnetizing curve is described by a continuous and smooth manner.Moreover a calculation method is also proposed based on the model.In the proposed method, the magnetizing branches are first solved by the semi explicit Runge Kutta algorithm, and then the transient responses can be obtained for the system network. A comparison has been made between calculated and experimental results and a better agreement appears.
关 键 词:电力系统 铁心元件网络 非线性励磁特性 暂态计算 数值计算
分 类 号:TM744[电气工程—电力系统及自动化]