摘 要:以大庆某化工厂石化废水二级处理出水作为回用于工业循环冷却水水源 ,通过对废水回用前后的水质分析和相关处理技术的调查 ,确定采用曝气生物滤池和臭氧生物活性炭处理工艺进行中试研究。试验结果表明 :经本工艺处理后 。The effluent of a secondary wastewater treatment plant treating petro chemical wastewater in Daqing Oil Field was appointed to reuse for the make up to circulating cooling water system. The data of water quality before and after reuse were studied, and technical investigation was done. A pilot plant with processes of aerobic bio filter (BAF), ozonization and biological activated carbon (BAC) treatment was conducted. The experimental results show that these processes are enough to produce water suitable to use for circulating cooling water system.