检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:安国银[1] 边疆[1] 彭波[1] 魏刚[1] 张保瑞[1] 周若明[1]
机构地区:[1]河北省电力试验研究所,河北石家庄050021
出 处:《河北电力技术》2003年第4期1-3,28,共4页Hebei Electric Power
摘 要:通过对一、二次风量测量装置的标定试验、炉膛布风板空板阻力试验以及料层厚度为500mm的料层阻力试验,确定风量标定系数及料层阻力曲线,找出临界流化风量,同时检查布风板布风均匀性和有关风机的出力特性,确定冷渣器排渣控制参数,为循环流化床锅炉的稳定、正常运行提供依据。Through the calibration of primary and secondary air measuring apparatuses,and test of air resistance of air distribution dampers and coal layer resistance at thickness of 500 mm, the air flow calibration coefficient and coal layer resistance curve are determined. The critical fluidizing air flow is found. In addition, the homogeneity of air distribution of the distribution dampers and the output characteristics of related fans are checked, and the slag-removing control parameters of slag cooler are determined. These provide a scientific basis for stable and normal operation of the CFB boiler.
分 类 号:TK229.6[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3