检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南京师范大学化学与环境科学学院,江苏南京210097 [2]东南大学自动化研究所,江苏南京210096
出 处:《水处理技术》2003年第4期244-246,共3页Technology of Water Treatment
摘 要:本文根据氮肥厂废水的特点,研究了高浓度氨氮废水的处理方法-吹脱法的除氨机理和氨氮去除率的影响因素。针对pH值和温度对氨氮去除率的影响,我们做了实验,结果表明若去除率要达到90%以上,pH值必须大于12且温度高于90℃。同时可以用CaO将废水的pH值调节到12以上。最后,针对这种废水的处理设计了可行的工艺方案。According to the characteristic of the waste water from nitrogenous fertillzer factory, the treatment method of ammonia-nitrogen waste water will high concentration, nitrogen removal mechanism of blow-denitrogenation and the affecting factors for ammonia-nitrogen removal were studied. In view of the influence of pH value and temperature on the removal rate of ammonia-nitrogen, the authors the experiment, the results showed that if the removal rate reaches to over 90%, pH value must be greater than 12, and temperature must be higher than 90℃; pH value can be adjusted over 12 with CaO. Finally, a feasible technologyical scheme was designed for the wastewater treatment.
关 键 词:氨 废水处理 设计 氮肥废水 吹脱法 机理 PH值 温度
分 类 号:X786[环境科学与工程—环境工程]