300MW锅炉高温过热器超温爆管问题的试验研究  

Experimental Study on the Overheat-Bursting Problem of a 300MW Boiler's High Temperature Superheater

在线阅读下载全文

作  者:施鸿飞[1] 赵发明[2] 徐新华[2] 徐献忠[2] 张富祥[1] 李立人[1] 

机构地区:[1]上海发电设备成套设计研究所,上海200240 [2]江苏常熟发电有限公司,江苏常熟215536

出  处:《发电设备》2003年第5期6-10,共5页Power Equipment

摘  要:对高温过热器出口段加装壁温测量在线检测系统和烟气温度的测点,确定锅炉在启动、220MW、300MW及运行工况改变时过热器出口管壁温度的变化情况,通过试验和分析计算,找出过热器超温爆管的原因,提出解决问题的办法。An extra temperature supervisory system was installed at the high temperature superheater's outlet and a number of gas temperature measuring locations were fixed as well. Then, after having taken down the superheater outlet wall's temperature variations during startup, at 220MW, 300MW and under operating conditions, the cause of overheatexplosion was revealed by additional analytical calculation. The paper presents suggestions for solving the problem.

关 键 词:锅炉 高温过热器 超温爆管 壁温 寿命评估 

分 类 号:TK223.32[动力工程及工程热物理—动力机械及工程]

 