检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]深圳大学师范学院,深圳518060 [2]华中师范大学化学系,武汉430079 [3]深圳市水质检测中心,深圳518001
出 处:《深圳大学学报(理工版)》2003年第3期69-74,共6页Journal of Shenzhen University(Science and Engineering)
摘 要:将GMK雾化器经改造后作为连续氢化发生装置,与ICP/AES联用后测定氢化元素,等离子体放电稳定,信号噪音小.元素的检出限比常规气动雾化降低1~2个数量级,相对标准偏差低于5%,回收率约为90%,可用于日常分析测定.Stop-flow GMK nebulizer has been used as a hydride generation device. The characteristics of the device were evaluated by means of measurements of As,Sb,Se detection limits and the repetition for the multi-measurements. The system has been applied to the analysis of biological samples. The recovery rates of selenium are about 90%. The results are satisfactory when compared with the standard reference material.