氢化法与ICP/AES联用测定样品中的As、Sb、Se  被引量:2

Determination of As,Sb,Se in Biological Samples with Hydride Generation Technique Combined with ICP/AES

在线阅读下载全文

作  者:王芳[1] 卢汉兵[2] 曹蕾[3] 唐立荣[1] 

机构地区:[1]深圳大学师范学院,深圳518060 [2]华中师范大学化学系,武汉430079 [3]深圳市水质检测中心,深圳518001

出  处:《深圳大学学报(理工版)》2003年第3期69-74,共6页Journal of Shenzhen University(Science and Engineering)

摘  要:将GMK雾化器经改造后作为连续氢化发生装置,与ICP/AES联用后测定氢化元素,等离子体放电稳定,信号噪音小.元素的检出限比常规气动雾化降低1~2个数量级,相对标准偏差低于5%,回收率约为90%,可用于日常分析测定.Stop-flow GMK nebulizer has been used as a hydride generation device. The characteristics of the device were evaluated by means of measurements of As,Sb,Se detection limits and the repetition for the multi-measurements. The system has been applied to the analysis of biological samples. The recovery rates of selenium are about 90%. The results are satisfactory when compared with the standard reference material.

关 键 词:氢化法 ICP/AES    GMK雾化器 蠕动泵 

分 类 号:O653[理学—分析化学]

 