氧化-混凝法处理碱性高砷废水的实验研究  被引量:6

The experimental research for treatment of alkaline wastewater with high concentration of arsenic by oxidation-flocculation

在线阅读下载全文

作  者:翟平[1] 刘如意[1] 张志[1] 廖昌华[1] 

机构地区:[1]广东工业大学环境科学与工程学院,广州510090

出  处:《环境污染治理技术与设备》2003年第11期52-55,共4页Techniques and Equipment for Environmental Pollution Control

摘  要:对碱性高砷废水的处理进行了研究 ,针对常规混凝法除砷的缺点提出了氧化 混凝工艺。结果表明 ,用氧化 混凝工艺除砷效果显著 ,废水经处理后砷含量低于 0 5mg/L ,符合国家排放标准。氧化 混凝除砷的最佳工艺条件为 :pH值为 6— 7,H2 O2 用量为 2 5 % ,氧化时间为 10min ,Fe2 (SO4) 3 用量为 2 5g/L ,PAM用量为 11 2 5mg/L。The treatment of alkaline wastewater with high concentration of arsenic has been studied We put forward the technology of oxidation_flocculation to overcome the demerits of conventional methods for removing arsenic The results showed that the effect of removing arsenic by oxidation flocculation is remarkable The content of arsenic is under 0 5 mg/L after the wastewater treatment. It measures up the national standards of letting water The best technical conditions are that pH is 6-7, the dosage of H 2O 2 is 2 5%, oxidation time is 10 minutes, the dosage of Fe 2(SO 4) 3 is 2 5 g/L, the dosage of PAM is 11 25 mg/L

关 键 词:氧化 混凝 碱性高砷废水 废水处理 

分 类 号:X703.1[环境科学与工程—环境工程]

 