检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]钢铁研究总院,北京100081
出 处:《冶金分析》2003年第5期1-5,共5页Metallurgical Analysis
摘 要:研究了辉光放电电流、放电电压、信号采集时间以及预溅射时间等因素对中低合金钢辉光光谱行为的影响,建立了辉光放电发射光谱法(GD-OES)同时测定中低合金钢中C,P,S,Si,Mn,Cu,Ni,Cr,Ti,Al,Co和B的方法。方法具有很好的准确度和精密度。The influence of glow discharge parameters,such as discharge current,voltage and integrating time on the intensities and stability of twelve elements in middle-low alloy steels as well as the spectral behaviour of the twelve elements in glow discharge were investigatedThen a method for multi-element simultaneous determination of C,Si,Mn,P,S,Cr,Ni,Ti,Cu,Co,B,Al in middle-low alloy steel was establishedThe optimal conditions for determination were selectedThe discharge voltage and current were 1100V and 50mA respectively;the integrating time and the pre-burn time were 10s and 60s respectivelyThe method was proved to be precise and accurate
关 键 词:辉光放电发射光谱 中低合金钢 GD-OES 光谱行为 放电电压 信号采集时间 预溅射时间
分 类 号:TG115.3[金属学及工艺—物理冶金]