阵列空间敏感编码技术在3D-MRCP中的应用  被引量:3

Application of array space sensitive coding technology in 3D-MRCP

在线阅读下载全文

作  者:潘善军 戴霄红 应琦[1] PAN Shanjun;DAI Xiaohong;YING Qi(Enze Hospital of Enze Medical Center,Taizhou 318053,P.R.China;Zhejiang Taizhou Enze Medical Center(Group)Luqiao Hospital,Taizhou 318050,P.R.China)

机构地区:[1]浙江省台州恩泽医疗中心(集团)恩泽医院,浙江台州318053 [2]浙江省台州恩泽医疗中心(集团)路桥医院,浙江台州318050

出  处:《医学影像学杂志》2019年第3期485-486,490,共3页Journal of Medical Imaging

摘  要:探讨阵列空间敏感编码技术(ASSET)在3D-MRCP中的应用价值。方法对48例MRCP检查的患者先进行常规3D-MRCP扫描,然后再行一次加ASSET的3D-MRCP扫描,对两组获得的原始图像分别进行最大强度投影(MIP)重建,并比较两组成像的诊断性能。结果两组图像的胆管及分支数目显示无差异(P>0.05),但是胆管及分支的边缘清晰度显示比常规的要高,差异有统计学意义(P<0.05)。结论加ASSET的3D-MRCP图像质量优于常规3D-MRCP。Objective To discuss the application value of the array spatial sensitivity encoding technique(ASSET) in 3 D-MRCP. Methods Routine 3 D-MRCP scan was performed on 48 patients undergoing MRCP examination. Then a ASSET 3 D-MRCP scan was performed. The original image of two groups were obtained by maximum intensity projection(MIP) reconstruction. And the difference of two groups of imaging diagnosis was compared. Results Bile duct and branch number in two group images showed no difference(P>0.05). But the edge sharpness of bile duct and branch was higher than the conventional display, the difference was statistically significant(P<0.05). Conclusion ASSET 3 D-MRCP image quality is better than conventional 3 D-MRCP.

关 键 词:磁共振成像 阵列空间敏感编码技术 胰胆管成像 

分 类 号:R445.2[医药卫生—影像医学与核医学]

 