催化湿式氧化法处理含酚废水  被引量:8

Research on phenol wastewater by catalytic wet oxidation

在线阅读下载全文

作  者:周文俊[1] 钱仁渊[1] 金鸣林[1] 史美仁[2] 

机构地区:[1]上海应用技术学院材料工程系,上海201101 [2]南京工业大学化学化工学院,江苏南京210009

出  处:《南京工业大学学报(自然科学版)》2004年第1期63-67,共5页Journal of Nanjing Tech University(Natural Science Edition)

摘  要:进行了CuO/Al2O3、CuO MnO2/Al2O3、CuO K2O/Al2O3、CuO/CeO2催化剂在160℃和1.6MPa的氧气压力条件下,催化氧化法处理含酚废水的实验,结果表明催化剂CuO/CeO2具有最高的催化活性,COD为3000mg/L左右含酚废水,反应50min后降解97%。并测定了在135~165℃和1.6MPa氧气压力下,加入催化剂CuO/Al2O3氧化含酚废水的COD与时间的的关系,求取了反应的动力学方程。初步探讨了氧分压和溶液的pH对催化氧化反应速率的影响。Treatment of phenol wastewater by catalytic wet oxidation at 160 ℃ and 1.6 MPa of O_2 over CuO/Al_2O_3?CuO-MnO_2/Al_2O_3?CuO-K_2O/Al_2O_2 and Cuo/CeO_2 was investigated. The results showed that CuO/CeO_2 had a highest catalytic activity. 50 min later, phenol wastewater (COD about (3 000) mg/L) was almost completely removed. The relation between COD and the time over CuO/Al_2O_3 _wat 135~165 ℃ and 1.6 MPa of O_2 was determined, and kinetic equation was obtaind. The affection about oxygen partial pressure and pH to reaction rate were also discussed.

关 键 词:催化湿式氧化法 废水处理 含酚废水 催化剂 动力学方程 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象