Optimum line reclosing time for the enhancement of interconnected power system stability  

Optimum line reclosing time for the enhancement of interconnected power system stability

在线阅读下载全文

作  者:蔡国伟 K. W. CHAN 孙鑫 谢东岩 

机构地区:[1]Dept. of Electric Power Engineering, Northeast China Institute of Electric Power Engineering [2]Dept. of Electrical Engineering,HongKong Polytechnic University

出  处:《Journal of Harbin Institute of Technology(New Series)》2003年第4期422-428,共7页哈尔滨工业大学学报(英文版)

基  金:SponsoredbytheNationalNaturalScienceFoundationofChina (GrantNo .5 99770 0 1) .

摘  要:Automatic line reclosing schemes used in an extra-high-voltage power system is an economical and effective means to maintain transient stability. A novel method is proposed in the paper to adaptively optimize the automatic line reclosing time after a transient fault for enhancement of interconnected power system transient stability. Both the study on the transient energy over network and the structure-preserving multi-machines power system model illustrate that the excessive convergence of potential energy on the lines with a certain cutset deteriorate power system stability, and therefore, an optimum line reclosing strategy can be established by minimizing the change in transient potential energy distribution across a cutset lines in the vicinity of the faulty line as an optimization target, and the optimal reclosure time is set to the time of minimum line phase angle difference. Without any pre-determined knowledge, the method is adaptive to various power system operation modes and fault conditions, and easy to implement because only a limited number of data measured at one location on a tie-line linking sub-networks are required. Simulations have been performed with the OMIB(One Machine and Infinite Bus System) and a real inter-connected power system to verify the applicability of the method proposed.Automatic line reclosing schemes used in an extra-high-voltage power system is an economical and effective means to maintain transient stability. A novel method is proposed in the paper to adaptively optimize the automatic line reclosing time after a transient fault for enhancement of interconnected power system transient stability. Both the study on the transient energy over network and the structure-preserving multi-machines power system model illustrate that the excessive convergence of potential energy on the lines with a certain cutset deteriorate power system stability, and therefore, an optimum line reclosing strategy can be established by minimizing the change in transient potential energy distribution across a cutset lines in the vicinity of the faulty line as an optimization target, and the optimal reclosure time is set to the time of minimum line phase angle difference. Without any pre-determined knowledge, the method is adaptive to various power system operation modes and fault conditions, and easy to implement because only a limited number of data measured at one location on a tie-line linking sub-networks are required. Simulations have been performed with the OMIB(One Machine and Infinite Bus System) and a real inter-connected power system to verify the applicability of the method proposed.

关 键 词:power system stability automatic line reclosing scheme network transient energy optimum reclosing time 

分 类 号:TM712[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象