动态浊度法定量检测替硝唑注射液中内毒素研究  被引量:13

Measurement of endotoxin in tinidazole injection using the kinetic-tur bidimetric technique

在线阅读下载全文

作  者:苑庆华[1] 芮菁[1] 华晓东[1] 唐元泰[1] 

机构地区:[1]天津市药品检验所,天津300070

出  处:《中国药学杂志》2003年第12期952-954,共3页Chinese Pharmaceutical Journal

基  金:天津市科委自然基金项目 (No .0 0 0 2 61)

摘  要:目的 对替硝唑注射液进行细菌内毒素动态浊度法检查实验 ,建立定量检测替硝唑注射液中细菌内毒素实验方法。方法 采用中国药典 2 0 0 0年版附录检测细菌内毒素动态比浊法。结果 替硝唑注射液用定量鲎试剂检测无干扰因素影响 ,内毒素回收率在 5 0 %~ 2 0 0 %范围内。OBJECTIVE: To establish the kinetic-turbidimetric technique for practical quality control on endotoxin content in tinidazole injection. METHODS: The kinetic-turbidimetric technique in Chinese pharmacopoeia 2000 edition was used. Interfence factors were investigated. RESULTS: Endotoxin spiked to tinidazole injection was recovered in a quantitative manner and neither inhibition nor enhancement effect was found. The endotoxin recovery was more than 50 percent and less than 200 percent. CONCLUSION: These results suggested that the kinetic-turbidimetric technique for bacterial endotoxin test was suitable for the detection of endotoxin in tinidazole injection.

关 键 词:动态浊度法 定量检测 替硝唑 注射液 内毒素 

分 类 号:R927.12[医药卫生—药学]

 