检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张权 李新[1] 翟文超[1] 刘恩超[1] 张艳娜[1] 郑小兵[1] ZHANG Quan;LI Xin;ZHAI Wenchao;LIU Enchao;ZHANG Yanna;ZHENG Xiaobing(Key Laboratory of Optical Calibration and Characterization,Anhui Institute of Optics and Fine Mechanics,CAS,Hefei 230031,China;University of Science and Technology of China,Hefei 230026,China)
机构地区:[1]中国科学院安徽光学精密机械研究所中国科学院通用光学定标与表征技术重点实验室,安徽合肥230031 [2]中国科学技术大学,安徽合肥230026
出 处:《应用光学》2019年第2期193-201,共9页Journal of Applied Optics
基 金:国家自然科学基金(61505222);国家自然科学基金青年项目(41705013);十三.五航天预研项目(D040401)
摘 要:介绍了自行研制的辐射仪器的光谱模块,其光谱范围覆盖可见-短波红外波段(400nm~2 500nm),讨论了光谱模块的装调方法并对装调结果进行了分析研究。辐射仪器由3个光谱模块组成,分别是可见波段光谱模块(400nm~1 000nm),近红外波段光谱模块(900nm~1 700nm)和短波红外波段光谱模块(1 600nm~2 500nm),光谱模块的探测单元均以平场凹面光栅分光,线阵探测器探测信号,光谱模块的光机组件主要包括光纤头、狭缝、反射镜组件、光栅组件和探测器组件等。鉴于光谱模块的光机装调效果与其光机设计息息相关,装调结果的好坏能反映光机设计的优劣,针对光谱模块的光机设计特点进行了光机装调。光机装调分析结果表明:3个光谱模块的波长分辨率分别优于4nm,15nm和20nm,达到了仪器的设计指标,验证了光机设计、装调的合理性。The spectral modules of self developed radiometer are introduced.The spectral range covers the visible-short wave infrared band(400 nm^2 500 nm).The methods of opto-mechanical assembly of spectral modules are discussed and the results of opto-mechanical assembly are analyzed.The radiometer consists of three spectral modules:the visible spectral module(400 nm^1 000 nm)(VIS for short),the near-infrared spectral module(900 nm^1 700 nm)(NIR for short),and the short wave infrared spectral module(1 600 nm^2 500 nm)(SWIR for short).The detection units of spectral module use the flat-field concave grating to diffract and focus different wavelengths,use the linear array detector to detect signals.The optical units of spectral modules consist of optical fiber,slit,assembly of reflector,assembly of grating and assembly of detector.Since the effect of opto-mechanical assembly is closely related to optomechanical design,the result of opto-mechanical assembly can reflect the advantages and disadvantages of opto-mechanical design.According to the characteristics of the opto-mechanical design of the spectral modules,the opto-mechanical assembly was carried out.The results of opto-mechanical assembly show that the wavelength resolution of the three spectral modules is better than 4 nm,15 nm and 20 nm,respectively.The design indexes of the spectral module are achieved,verifying the rationality of the opto-mechanical design.
分 类 号:TH74[机械工程—光学工程] TN21[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.138.199.24