作 者:王世亮[1] 储成顶[1] 周浩炳[1] 张海燕[2] 谢正[1] 叶红杨[1]
机构地区:[1]合肥工业大学控释药物研究室 [2]安徽医科大学理化中心,合肥230032
出 处:《中国新药杂志》2003年第12期1026-1029,共4页Chinese Journal of New Drugs
摘 要:目的:测定植入用缓释氟尿嘧啶中环已烧残留量。方法:研碎供试品,置针管中于60℃保温作气固顶空平衡,顶空气以气相色谱法测定,氢焰检测器,SE-30固定相,柱温80℃。结果:方法的精密度RSD为2.8%,回收率为101.4%,10~110ng·mL^(-1)范围内线性良好,检出限为3.4ng·mL^(-1)。结论:为类似难溶性固体药物的有机溶剂残留量检测提供了可靠的方法。Objective: To determine cyclohexane, a residual solvent, in fuorouracil sustained-release subcutaneous implant. Methods: Pulverized sample was put into a syringe and maintained at 60^ for balance. The cyclohexane was determined with GC using SE-30 as stationary phase, a column temperature of 80℃, and a hydrogen flame detector. Results: The liner range of cyclohexane was 10-110ng·mL-1( r = 0. 999 8,n =6) with a detection limit of 3. 4ng·mL-1. The average recovery was 101.4% with a RSD of 2. 8 % . Conclusion: A reliable method was provided by the authors for determination of residual solvent in sparingly soluble drugs similar to fluorouracil.
关 键 词:气相色谱法 气固顶空法 环己烷 植入用缓释氟尿嘧啶
分 类 号:R917[医药卫生—药物分析学] R927.2[医药卫生—药学]