基于模糊决策树的变电站电压无功控制方法研究  被引量:4

Study of voltage and reactive power control approach based on fuzzy decision trees for substations

在线阅读下载全文

作  者:白建社[1] 樊波[1] 薛钧义[1] 

机构地区:[1]西安交通大学电气工程学院,陕西西安710049

出  处:《中国电力》2003年第12期62-65,共4页Electric Power

摘  要:变电站的电压无功控制是保证电能质量和电力系统安全可靠运行的重要措施。本文分析当前电压无功控制方法存在的不足,把模糊决策树应用到这一领域,提出基于模糊决策树的变电站电压无功控制方法。模糊决策树融合了模糊理论和决策树的优点,不仅能很好地解决电压越限的模糊边界问题,而且能依据调压控制的限制条件、优化原则和设备保护闭锁等信息进行综合决策,以实现电容器和变压器分接头在变电站各种运行状态下的最佳配合。用于某110kV变电站的实验表明,本方法能提高电压质量、减少设备调节次数,具有良好的控制性能。The voltage and reactive power control of substation is an important approach that ensures the voltage quality and power system running in security and reliability.This paper analyzes the shortage of the methods at present,and proposes a new method of the voltage and reactive power control,which is based on the fuzzy decision trees(FDT).The proposed method solves the fuzzy boundary problem of voltage and reactive power control and overcomes the shortage of the fixed boundary control methods.In addition,with the synthetically decision-making capability of the fuzzy decision trees,it combines the limited conditions and optimized standards in voltage control and the protective and locked information in substation,and realizes the best coordination of capacitors(reactors)and tap change of transformer in various running status of substation.The experimental result for110kV substation shows that the proposed method improves greatly the performance of voltage and reactive power control and advances the voltage quality,which has the well application foreground.

关 键 词:变电站 电力系统 模糊决策树 电能质量 电压无功控制 

分 类 号:TM761[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象