检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李士民[1]
机构地区:[1]中国人民解放军一五三医院,河南郑州450042
出 处:《中国烧伤创疡杂志》2003年第4期321-322,共2页The Chinese Journal of Burns Wounds & Surface Ulcers
摘 要:目的 :解决大面积烧伤休克期静脉反复穿刺失败的难题。方法 :采用皮肤切开套管针静脉穿刺置管代替静脉切开。结果 :本组 2 4例穿刺成功率 10 0 % ,比静脉切开节时省力 ,有效地保护了静脉的重复使用 ,无 1例发生静脉炎 ,静脉栓塞及套管脱出等静脉置管并发症。结论 :皮肤切开套管针静脉穿刺置管适合于烧伤复苏治疗 。Objective:To solve the problem of the failure of trocar venipuncture cannulation, in patients with large area burn at the shock stage.Method: A skin incision trocar veinipucture cannula was used to replace vein incision. Result: This skin incision trocar veinipucture cannula had been used in 24 patients. The successful rate was 100%. This method is easy and simple. No phlebitis, no phlebothrombosis and no loosening of the cannula occurred. Conclusion: Skin incision trocar veinipucture cannula is very suitable to be used in burn patients at the resuscitation stage.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30