新型光亮镀锡铅钴合金镀液中微量钴的快速测定  

Rapid Determination of Micro Cobalt in New Bright Sn-Pb-Co Alloy Plating Bath

在线阅读下载全文

作  者:罗序燕[1] 钟洪鸣[1] 

机构地区:[1]南方冶金学院材化学院,江西赣州341000

出  处:《表面技术》2004年第2期70-71,74,共3页Surface Technology

基  金:江西省自然科学基金资助项目(985023)

摘  要: 采用5 Br PADAP光度法测定酸性光亮镀锡铅钴合金镀液中的微量钴,优选出最佳测定波长。研究了酸度、Tween 80的用量、甘油的用量、显色剂的用量和干扰离子对测定的影响,钴金量在0~12μg/25ml范围内,符合郎比定律。该方法快速简便,可用于实际应用当中。Micro cobalt in new acidic bright Sn-Pb-Co alloy was determined by spectrophotometric method using 2-(5-bromo-2-pyridylazo)-5 diethylaminophenol (5-PADAP) as chromogenic agent,and the optimal measuring wavelength was selected.The effects of acidity,concentration of Tween-80,glycerin and chromogenic agent,and interfering ions were studied.The relationship between absorbance and cobalt content following Beer's law provided that cobalt content was among 0 and 12/25ml.The method is both fast and high veracity in addition to its simplicity and has good value for application.

关 键 词: 分光光度法 光亮镀 5-BR-PADAP 锡钴铅合金 

分 类 号:TG115.335[金属学及工艺—物理冶金] TQ153.2[金属学及工艺—金属学]

 