检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨小明[1] 熊海[1] 刘静[1] 潘小平[2] 李轩[3] 尚家云[1] 雷梅[1] 吕先慧[1]
机构地区:[1]四川大学华西附四院,成都610041 [2]四川大学公共卫生学院卫生统计教研室 [3]四川省射洪县中医院
出 处:《预防医学情报杂志》2004年第2期117-118,共2页Journal of Preventive Medicine Information
摘 要:目的 探讨DXA测量骨密度的准确性。方法 用DXA(前后位扫描 )测量 5具浸泡在 10cm水深中的猪腰段脊柱 ,共计 2 0例椎骨 ,将测量的结果与灰重及灰重密度计算相关性。结果 骨矿含量 (BMC)与灰重的相关性为 0 95 ,P <0 0 1,而骨密度 (BMD)较差r =0 4 7,(P <0 0 5 )。结论 DXA测量骨密度中骨矿含量 (BMC)较准确 ,而骨密度 (BMD)Objective To study the accuracy of dual energic X-ray absorption(DXA) measuring bone density. Metheds 20 pig lumbar vertebreas from 5 pigs were immersed 10 centimeters below water horizon and measured by DXA(anterior-posterior view ,AP).The data of DXA was compared with bone ash analysis.Results Bone mineral content (BMC) and bone ash weigtht were correlated at high level of significance with r=0.95 P<0.01, while bone mineral density(BMD) was showed a lower correlation with bone ash density (r=0.47,P<0.05). Conclusions DXA evaluates bone mineral content is more accurate than bone mineral density
分 类 号:R814[医药卫生—影像医学与核医学]