CT重建椎弓根轴线投影点定位研究  被引量:3

The position study of the projection point of the lumbar pedicle axis on the posterior aspect by reconstructed CT

在线阅读下载全文

作  者:李兵[1] 姜保国[1] 傅忠国[1] 张殿英[1] 杜湘珂[1] 王天兵[1] 

机构地区:[1]北京大学人民医院创伤骨科,北京市100044

出  处:《中国脊柱脊髓杂志》2003年第9期551-554,共4页Chinese Journal of Spine and Spinal Cord

摘  要:目的:建立椎弓根螺钉最佳入钉点,提高椎弓根螺钉内固定术的准确性和安全性.方法:高速螺旋CT共扫描检查40例国人的200个L1~L5脊椎.重建后测量400个椎弓根的入点坐标(x,y),即椎弓根轴线在椎骨后表面的投影点与后正中线的距离(x)及与横突中线的垂直距离(y).结果:x坐标从L1~L5逐渐增大,男性大于女性(P<0.05);y坐标从L1到L4逐渐下移,在L4与横突中线接近重叠,但L5突然上升,与L2节段水平相当,L1~L5 y坐标基本上都在横突中线以上,但每组数据变异较大.就y坐标而言,椎弓根轴线投影点与传统入点比较均有差异.结论:横突中线是椎弓根螺钉置入的重要参照标志,但椎弓根轴线投影点并不在横突中线上,不同个体、节段之间y坐标存在的较大差异是高误置率发生的重要原因.对个体而言,术前常规通过CT测量椎弓根轴线在椎骨后表面的投影点数据对椎弓根螺钉的置入有重要指导意义.Objective:To establish the best starting point for fixing a pedicle screw to the axial center of the pedicle,which promotes safety and accuracy of transpedicular procedures.Method:A total of200vertebrae from L1~L5of40Chinese people were scanned on a GE LightSpeed QX/i computerized tomographic scanner in the axial plane.After images were reconstructed,the coordinates including the distance from the projection point of the lumbar pedicle axis to the midline of back(x)and to the midline of transverse process(y)were measured.Result:X coordinates increased from L1to L5,which showed male was longer than female(P<0.05).The average of y coordinates stepped down from L1to L4where it was very close to mid-transverse process.But y was up to L5.Most of y coordinates were above mid-TP(transverse process),where as the variance was considerable.As far as y was concerned,there was significant difference between projection point and traditional position ways.Conclusion:Mid-TP was thought as an important landmark during the transpedicular procedures.But the projection point of lumbar pedicle is not in mid-TP.There are diversity in different person and segments,which become the main issue of high misplace rates.The coordinates of projection point of lumbar pedicle axis obtained individually from reconstructed CT images preoperatively could ensure utmost safety and accuracy of transpedicular procedures.

关 键 词:CT检查 轴线 投影点 椎弓根螺钉 内固定 最佳入钉点 

分 类 号:R687.33[医药卫生—骨科学] R816.8[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象