锰铜传感器保护介质对雷管输出记录波形的影响  被引量:8

Impact of Manganin Transducer Protective Medium on Detonator's Output Record Waveform

在线阅读下载全文

作  者:韩秀凤[1] 严楠[1] 蔡瑞娇[1] 

机构地区:[1]北京理工大学爆炸灾害预防与控制国家重点实验室,北京100081

出  处:《北京理工大学学报》2004年第5期462-465,共4页Transactions of Beijing Institute of Technology

基  金:国家部委预研项目(41305060000)

摘  要:提出在锰铜传感器前方加保护介质测试有底壳爆炸元件的轴向输出.采用有机玻璃板和Mylar膜作为保护介质,测试1号电雷管的底部输出;运用流体力学理论对所得波形进行分析;结果表明,锰铜压阻法测试有破片产生的爆炸元件时,加1mm厚有机玻璃板优于加0.05~0.10mm的Mylar膜.When measuring the axial output of an explosive element with bottom case by a manganin sensor, a protective medium should be added to the front of the sensor. PMMA and Mylar films are selected to protect the sensor when measuring a No.1 electric detonator. By analyzing the measured waveform hydrodynamically, the following conclusion was obtained: the use of 1 mm PMMA compared better than a 0.05~0.10 mm Mylar film when measuring explosive elements with fragments.

关 键 词:雷管 锰铜传感器 冲击波压力 