胃镜引导插管小肠双对比造影方法研究  被引量:1

Double contrast examination of small intestine with gastroscopic guided intubation

在线阅读下载全文

作  者:李少明[1] 王丽萍[2] 司徒鹏[3] 方先来[1] 黄汉华[1] 何丽娟[3] 陈斌[3] 

机构地区:[1]韶关市粤北人民医院放射科,广东512025 [2]韶关市粤北人民医院消化内科,广东512025 [3]韶关市粤北人民医院内镜科,广东512025

出  处:《放射学实践》2003年第7期494-495,共2页Radiologic Practice

摘  要:目的 :探讨小肠双对比造影检查的有效方法。方法 :72例受检者被随机分成 2组 ;试验组 ( 3 6例 )应用研制的小肠造影导管 ,在胃镜直视下钳夹导管头端并送达十二指肠水平部 ,头端气囊充气固定导管 ,退出胃镜后 ,经导管灌注适量稀钡胶浆及空气行小肠双对比造影。对照组 ( 3 6例 )采用改进的F9心导管在透视下插管。结果 :实验组插管成功 3 5例 (成功率 97.1% ) ,对照组插管成功 2 7例 (成功率 75 % )。结论 :研制专用的小肠造影导管并经胃镜引导插管行小肠双对比造影检查 。Objective:To investigate the method of double contrast examinations of small intestine.Methods:72 cases were randomized into two groups:group A and group B.36 cases of the group A were performed small intestine double contrast examination using a special tube.The tube was delivered to the horizontal part of duodenum as desired with gastroscopic guidance,then the balloon at the tip of catheter was inflated to fix the tube at the position and the gastroscope was withdrawn.The small intestine was visualized by injecting the diluted barium sulfate suspension and air via the tube as desired .On the other hand,the group B of 36 cases was performed with modified F9 cardiac catheter without gastroscopic guidance.Results:The success rate of intubation was 97.1% (35/36) in the group A and 75% (27/36) in the group B. Conclusion: intubation under gastroscopic guidance employed for small intestine double contrast examination is superior to conventional intubation method.

关 键 词:胃镜 小肠造影导管 双对比造影 小肠器质性病变 

分 类 号:R816.5[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象