检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王秀菊[1]
机构地区:[1]阿城继电器股份有限公司电源系统公司,阿城150302
出 处:《电源世界》2004年第4期45-49,共5页The World of Power Supply
摘 要:本文通过分析蓄电池运行常见的现象即电池失效模式和内阻的关系,研究了蓄电池在线监测管理系统应解决的关键问题,主要包括:(1)监测管理系统的合理结构;(2)电池单体的内阻数据在蓄电池监测系统的可靠性;(3)内阻和剩余容量关系。文中结合电池管理系统在直流操作系统中的应用进行了相关论述,该系统提高了直流电源运行的可靠性。The paper studies the crux that the battery on-line monitor management system solve according to the analysis of the running battery,the relation between the model of abeyance and internal resistance.Including:(1)the reasonable structure of monitor;(2)the reliability of the internal resistance data of single battery in the battery monitor system;(3)the relation between internal resistance and the rest of capacity.The paper discusses the use of the battery management system in DC operating system.The system improves the reliability of the running direct supply.
关 键 词:蓄电池内阻 失效模式 在线监测 阀控式铅酸蓄电池
分 类 号:TM912.1[电气工程—电力电子与电力传动]