摘 要:在碱性介质中,硫酸小诺霉素能被N 溴代琥珀酰亚胺(NBS)氧化,在荧光素的增敏作用下,产生化学发光。基于此,建立了测定痕量硫酸小诺霉素的流动注射化学发光分析法。硫酸小诺霉素在0.5~100μg·mL-1的浓度范围内与化学发光强度呈良好的线性关系,检出限(3σ)为0.08μg·mL-1,对5μg·mL-1的硫酸小诺霉素连续测定11次,相对标准偏差为1.8%。将本方法用于制剂中硫酸小诺霉素的分析,结果满意。A new method for the determination of micronomicin with flow injection chemiluminescence was described. It was based on the chemiluminescence during the oxidation of micronomicin by N-bromosuccinimide (NBS) in alkaline medium in the presence of fluorescein as energy transfer. This method was sensitive, simple, rapid and reproducible. The linear range for micronomicin was 0.5~100 μg·mL^(-1 )with the relative standard deviation of 1.8% (c=5.0 μg·mL^(-1), n=11). The detection limit (3σ) was (0.08) μg·mL^(-1). The recommended method has been successfully used for the analysis of commercial formulation with satisfactory results.