电化学发光免疫检测TSH,T3和T4之间相关性研究  被引量:3

Research the correlation among the ECLI detection of TSH,T3 and T4

在线阅读下载全文

作  者:周万军[1] 柳永和[1] 唐孟萱[1] 

机构地区:[1]中南大学湘雅医学院检验系,湖南长沙410013

出  处:《中国现代医学杂志》2004年第11期119-120,共2页China Journal of Modern Medicine

摘  要:目的观察电化学发光免疫检测血清TSH,T3,T4之间相关性。方法将515例临床标本分为治疗组和未治疗组进行TSH,T3,T4检测,并对此3项指标间相关性进行统计学分析。结果TSH/T3,TSH/T4,T3/T4之间的相关系数未治疗组分别为0.464,0.575,0.945,治疗组为0.229,0.262,0.868。结论此两组中TSH虽然与T3,T4间具有直线相关关系,但相关系数小,无医学意义;T3与T4间具有直线相关关系,且相关系数较大,具有一定的医学意义。Objective:To observe the correlation among the ECLI detection of TSH,T3and T4.Meth-ods:Divided the515clinical blood samples into un-treated group and treated group and employed ECLI to detect the TSH,T3and T4,then statistically analyzed the correlation among them.Results:The correlation coefficients of TSH/T3,TSH/T4and T3/T4in un-treated group were0.464,0.575and0.945while in treated group were0.229,0.262and0.868,respectively.Conclusions:In these two groups,though TSH has linear correlation with T3and T4,correlation coefficients are low,so they have no medical significance;T3has lin-ear correlation with T4and the correlation coefficient is high,so it has medical significance.

关 键 词:电化学发光 检测 相关性 

分 类 号:R392.11[医药卫生—免疫学] R581[医药卫生—基础医学]

 