出 处:《土木工程》2019年第3期728-734,共7页Hans Journal of Civil Engineering
基 金:扬州大学大学生科技创新基金资助X20180429.
摘 要:空气源热泵以空气作为低位热源,具有取热方便、节能、环保等优点。但是空气源热泵在北方地区应用时存在低温下供热性能下降等问题。本文主要阐述了空气源热泵的低温运行特性以及准二级压缩技术,对比准二级压缩式热泵系统与单级压缩式热泵系统在冬季的供热性能。结果表明,在环境温度低于?4.78℃时,准二级压缩式热泵系统的性能优于单级压缩式热泵系统。The air source heat pump uses air as a low-level heat source,which has the advantages of conven-ient heat extraction,energy saving and environmental protection.However,when the air source heat pump is applied in the northern region,there are problems such as a decrease in heating performance at a low temperature.This paper mainly describes the low temperature characteris-tics of air source heat pump and quasi-secondary compression technology,and compares the heating performance of quasi-secondary compression heat pump system and single stage com-pression heat pump system in winter.The results show that the performance of the qua-si-secondary compression heat pump system is better than that of the single-stage compression heat pump system when the ambient temperature is lower than?4.78?C.
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]