检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海理工大学能源与动力工程学院,上海 [2]东莞新能源研究院,广东 东莞 [3]中科院工程热物理研究所,北京 [4]广东省科技基础条件平台中心,广东 广州
出 处:《建模与仿真》2023年第2期1246-1256,共11页Modeling and Simulation
摘 要:本文建立了基于内燃机余热深度利用吸收式制冷系统模型,对比了有无缸套水余热利用系统间的差异性,探究了烟气与缸套水进口温度和流量变化对系统性能的影响。结果表明,通过对烟气和缸套水的梯级利用,系统实现更高的制冷量,但制冷系数更小,制冷量随着烟气与缸套水进口温度与流量升高而增大,制冷系数随着烟气进口温度与流量升高而迅速增大并逐渐平稳,随着缸套水进口温度与流量升高而减小。烟气–热水型系统模拟研究为吸收式制冷机组余热利用技术提供新的思路与数据支撑。In this paper, an absorption refrigeration system model based on the deep utilization of waste heat of an internal combustion engine was established. The differences between the systems with and without cylinder liner water were compared, and the effects of temperature and flow at the inlet of flue gas and cylinder liner water on the system performance were investigated. The results show that by using the flue gas and liner water step by step, the system achieves a higher cooling capacity, but the coefficient of performance (COP) is smaller. The cooling capacity increases with the increase of the inlet temperature and flow of flue gas and liner water, the COP increases rapidly with the in-crease of flue gas inlet temperature and flow and gradually becomes stable, and the COP decreases with the increase of the inlet temperature and flow of liner water. The simulation study of flue gas-hot water type system provides a new idea and data support for waste heat utilization technol-ogy of absorption refrigeration units.
关 键 词:吸收式制冷系统 制冷系数 制冷量 进口温度 吸收式制冷机组 梯级利用 系统模拟 余热利用技术
分 类 号:TB6[一般工业技术—制冷工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7