双配体Co-MOF对三乙胺的气敏检测  

Gas Sensitive Detection of Triethylamine by Double Ligand Co-MOF

在线阅读下载全文

作  者:李百静 

机构地区:[1]哈尔滨师范大学物理与电子工程学院,黑龙江 哈尔滨

出  处:《材料科学》2025年第2期266-272,共7页Material Sciences

摘  要:本文以对苯二甲酸和二甲基咪唑为配体,采用简单的水热方法结合煅烧处理,制备了双配体Co-MOF,对它进行了XRD,TG,SEM,TEM等的表征,同时也对材料进行了详细的气敏测试,结果表明,双配体Co-MOF在200℃对100 ppm的三乙胺响应为7.4,且有着较短的响应恢复时间和较好的选择性,并解释了气敏机理。In this paper, terephthalic acid and dimethylimidazole were used as ligands, and a simple hydrothermal method combined with calcination treatment was used to prepare the double-ligand Co-MOF, which was characterized by XRD, TG, SEM, TEM, etc. At the same time, the materials were also tested for detailed gas sensitivity. The results showed that the double-ligand Co-MOF responded to 100 ppm of triethylamine at 200˚C for 7.4, and had a short response recovery time and good selectivity. The gas sensing mechanism was explained.

关 键 词:MOF材料 三乙胺 气敏检测 

分 类 号:O64[理学—物理化学]

 