检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吕药灵
机构地区:[1]上海市城市建设设计研究总院(集团)有限公司环境与交通研究院,上海
出 处:《水污染及处理》2024年第3期50-58,共9页Water Pollution and Treatment
摘 要:通过小试试验、中试试验、工程项目生产实践开展了活性焦工艺去除难降解有机物的研究。结果表明,活性焦吸附COD为非均匀多分子层吸附,静态理论吸附量约199.45~260.65 mg COD/(g活性焦)。吸附柱设置形式对吸附效果略有影响,动态累积吸附量约为89.8 mg COD/(g活性焦)~96.0 mg COD/(g活性焦)。生产项目实践发现,活性焦应用于污水厂深度处理单元能够实现COD有效去除,出水水质达到污水厂排放标准要求。The removal of Non-biodegradable organic matter by activated coke process was studied through small-scale, pilot-scale experiments and engineering practice. The results show that the adsorption of COD by activated coke is non-uniform multi-molecular layer adsorption, and the static theoretical adsorption capacity is about 199.45~260.65 mg COD/(g activated coke). The arrangement of adsorption column has a slight influence on the adsorption effect, and the dynamic cumulative adsorption amount is about 89.8 mg COD/(g active coke)~96.0 mg COD/(g active coke). The application of activated coke in advanced treatment unit of wastewater treatment plant can effectively remove COD, and the effluent quality can meet the discharge standard of wastewater treatment plant.
分 类 号:X70[环境科学与工程—环境工程]