摘  要:为了适应水文现代化要求,积极推进水文现代化建设,加快新技术新仪器投产使用,实现流量自动化实时测验,小河坝水文站投产使用H-ADCP流量测验设备,实现了流量自动化监测,通过近几年的数据对比分析,系统误差、标准差都满足规范要求,数据稳定,精度可靠,达到了流量报讯要求。In order to meet the requirements of hydrological modernization, actively promote the modernization of hydrology, speed up the use of new technologies and new instruments, and realize the automatic real-time test of flow, Xiaoheba Hydrological Station has put into operation the use of H-ADCP flow test equipment to realize automatic flow monitoring, through the data comparison analysis in recent years, system error, standard deviation meet specification requirements, data stability, reliable accuracy, meet the flow dispatch requirements.

关 键 词:ADCP H-ADCP 流量测验 水文现代化 误差 

分 类 号:P33[天文地球—水文科学]

 