Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header  被引量:2

Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header

在线阅读下载全文

作  者:Dongyi Li Zhongguang Fu Qiang Zhang Ting He 

机构地区:[1]School of Energy,Power and Mechanical Engineering North China Electric Power University Beijing,China

出  处:《Engineering(科研)》2013年第1期66-68,共3页工程(英文)(1947-3931)

摘  要:The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.

关 键 词:SUPERHEATER OUTLET HEADER FINITE ELEMENT Method Stress CONCENTRATION 

分 类 号:O3[理学—力学]

 