Study of Optimal Parameters of Improved 1RX Regenerator  

Study of Optimal Parameters of Improved 1RX Regenerator

在线阅读下载全文

作  者:Avazbek Azamatovich Obidov Shavkat Olimdjanovich Mamadjanov Avazbek Azamatovich Obidov;Shavkat Olimdjanovich Mamadjanov(Department of Technological Machines and Equipment, Namangan Institute of Engineering and Technology, Namangan, Uzbekistan)

机构地区:[1]Department of Technological Machines and Equipment, Namangan Institute of Engineering and Technology, Namangan, Uzbekistan

出  处:《Engineering(科研)》2023年第5期291-300,共10页工程(英文)(1947-3931)

摘  要:In this article, researches on improvement of 1RX regenerator used in cleaning processes of cotton ginning enterprises were carried out. The effect of changing the parameters of the new working body—rubber-plate drum and machine inlet on the efficiency of cotton separation was studied in the research, and the maximum level of efficiency of separation was determined. In this paper work, the main factors affecting the efficient operation of the regenerator were identified, their value limits were determined, and research was conducted using the mathematical planning method. As a result, effective operation of the improved 1RX cotton regenerator was observed at the value of the given factors, that is, the separation efficiency was 99.5%, the cleaning efficiency was higher than 88.7%, and the amount of seed cotton in the waste was reduced lower than 2.5%.In this article, researches on improvement of 1RX regenerator used in cleaning processes of cotton ginning enterprises were carried out. The effect of changing the parameters of the new working body—rubber-plate drum and machine inlet on the efficiency of cotton separation was studied in the research, and the maximum level of efficiency of separation was determined. In this paper work, the main factors affecting the efficient operation of the regenerator were identified, their value limits were determined, and research was conducted using the mathematical planning method. As a result, effective operation of the improved 1RX cotton regenerator was observed at the value of the given factors, that is, the separation efficiency was 99.5%, the cleaning efficiency was higher than 88.7%, and the amount of seed cotton in the waste was reduced lower than 2.5%.

关 键 词:REGENERATOR COTTON Impurities Rubber-Plate Drum Cotton Piece Brush Drum Separation Effect Enterprise Plate Axis Parameter Working Body Grate-Bar Grid 

分 类 号:TK1[动力工程及工程热物理—热能工程]

 