检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Mahamat Adoum Abdoulaye Gabriel Jean Philippe Tevi Djicknoum Diouf Amadou Seidou Maiga Mahamat Adoum Abdoulaye;Gabriel Jean Philippe Tevi;Djicknoum Diouf;Amadou Seidou Maiga(LEITER, Laboratoire Electronique, Informatique, Télécommunication et Energies Renouvelables, Université Gaston Berger, Saint-Louis, Sénégal)
出 处:《Journal of Power and Energy Engineering》2020年第7期55-70,共16页电力能源(英文)
摘 要:This paper investigates the impact of the intermittency of the photovoltaic (PV) power plants on the electric grid frequency management and the consequences that can occur. To meet these purposes, three years data of the Senegalese grid frequency are used, combined with three PV power plants data since their starting-up. Using these data, we analyzed two days of heavily disturbed operation of the Senegalese grid in order to emphasize the real impact of the presence of PV power plants on the electrical grid. Our study has highlighted that how the intermittency of photovoltaic power plants affects frequency management. It obviously appears that the PV production curves follow the irradiation variations. Instantaneous variations of PV production make it difficult to manage the grid frequency leading to more frequent load shedding as we have shown with the data after the commissioning of the PV power plants. We also estimate the power then energy losses during the load shedding induced by the PV integration on the power grid by comparing a period corresponding to one month before (February 2017) and one month after (February 2018) the integration of variable PV production.This paper investigates the impact of the intermittency of the photovoltaic (PV) power plants on the electric grid frequency management and the consequences that can occur. To meet these purposes, three years data of the Senegalese grid frequency are used, combined with three PV power plants data since their starting-up. Using these data, we analyzed two days of heavily disturbed operation of the Senegalese grid in order to emphasize the real impact of the presence of PV power plants on the electrical grid. Our study has highlighted that how the intermittency of photovoltaic power plants affects frequency management. It obviously appears that the PV production curves follow the irradiation variations. Instantaneous variations of PV production make it difficult to manage the grid frequency leading to more frequent load shedding as we have shown with the data after the commissioning of the PV power plants. We also estimate the power then energy losses during the load shedding induced by the PV integration on the power grid by comparing a period corresponding to one month before (February 2017) and one month after (February 2018) the integration of variable PV production.
关 键 词:Intermittency Frequency Fluctuation Energy Loss Power Loss Fluctuating Power
分 类 号:TP3[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222