Detection and Evaluation of a Migrated Timber Structure House  

Detection and Evaluation of a Migrated Timber Structure House

在线阅读下载全文

作  者:Mingnan Ji Mingnan Ji(Inspection and Certification Co., Ltd., Beijing, China)

机构地区:[1]Inspection and Certification Co., Ltd., Beijing, China

出  处:《Modern Mechanical Engineering》2024年第4期73-81,共9页现代机械工程(英文)

摘  要:This article takes the inspection and appraisal of a certain migratory wooden structure as the backdrop, presents the inspection process of the wooden structure. Upon on-site examination, it was discovered that the connection (or node) construction mode of the building was correct. Only local surface flaws were present, and the operation was normal. The stress wave velocity of the randomly inspected wooden columns with surface cracking was close to the critical velocity, suggesting that no obvious cavities or decay defects existed within the measured wooden components. Based on the inspection outcomes, finite element computations were carried out for the wooden structure, arriving at the conclusion that the maximum stress value of the wooden members was smaller than the designed value of wood strength, and the vertical bearing capacity conformed to the requirements of the specifications. And rationally offered relevant treatment suggestions, providing a reference for the inspection and identification of such projects.This article takes the inspection and appraisal of a certain migratory wooden structure as the backdrop, presents the inspection process of the wooden structure. Upon on-site examination, it was discovered that the connection (or node) construction mode of the building was correct. Only local surface flaws were present, and the operation was normal. The stress wave velocity of the randomly inspected wooden columns with surface cracking was close to the critical velocity, suggesting that no obvious cavities or decay defects existed within the measured wooden components. Based on the inspection outcomes, finite element computations were carried out for the wooden structure, arriving at the conclusion that the maximum stress value of the wooden members was smaller than the designed value of wood strength, and the vertical bearing capacity conformed to the requirements of the specifications. And rationally offered relevant treatment suggestions, providing a reference for the inspection and identification of such projects.

关 键 词:Wooden Structure Stress Wave Inspection Structural Appraisal 

分 类 号:TG1[金属学及工艺—金属学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象