出 处:《World Journal of Engineering and Technology》2016年第2期313-324,共12页世界工程和技术(英文)
摘 要:This paper investigates the effects of site based parameters such as ambient temperature, humidity, altitude and heat transfer characteristic of a dual pressure heat recovery system on the performance of the combined cycle power plant within an equatorial environment. The bulk heat utilization and configuration of a dual pressure heat recovery system are investigated. It is observed that the heat system configuration play a vital role in optimizing the combined cycle overall performance, which has proportionality relationship with the operating ambient temperature and relative humidity of the gas turbine. The investigation is carried out within the ambient temperature range of 24℃ to 35℃, relative humidity of 60% to 80%, and a high level steam pressure of 60 bar to 110 bar. The results show that at 24℃ ambient temperature, the heat recovery system has the highest duty of 239.4 MW, the optimum combined cycle power output of 205.52 MW, and overall efficiency of 47.46%. It further indicates that as the ambient temperature increases at an average exhaust gas temperature of 530℃ and mass flow of 470 kg/s, the combined cycle power output and efficiency decrease by 15.5% and 13.7% respectively under the various considerations. This results from a drop in the air and exhaust mass flow as the values of the site parameters increase. The overall results indicate that decreasing the ambient temperature at optimum exhaust gas flow and temperature increases the heat recovery system heat duty performance, the steam generation, overall combined cycle power output and efficiency, which satisfies the research objective.This paper investigates the effects of site based parameters such as ambient temperature, humidity, altitude and heat transfer characteristic of a dual pressure heat recovery system on the performance of the combined cycle power plant within an equatorial environment. The bulk heat utilization and configuration of a dual pressure heat recovery system are investigated. It is observed that the heat system configuration play a vital role in optimizing the combined cycle overall performance, which has proportionality relationship with the operating ambient temperature and relative humidity of the gas turbine. The investigation is carried out within the ambient temperature range of 24℃ to 35℃, relative humidity of 60% to 80%, and a high level steam pressure of 60 bar to 110 bar. The results show that at 24℃ ambient temperature, the heat recovery system has the highest duty of 239.4 MW, the optimum combined cycle power output of 205.52 MW, and overall efficiency of 47.46%. It further indicates that as the ambient temperature increases at an average exhaust gas temperature of 530℃ and mass flow of 470 kg/s, the combined cycle power output and efficiency decrease by 15.5% and 13.7% respectively under the various considerations. This results from a drop in the air and exhaust mass flow as the values of the site parameters increase. The overall results indicate that decreasing the ambient temperature at optimum exhaust gas flow and temperature increases the heat recovery system heat duty performance, the steam generation, overall combined cycle power output and efficiency, which satisfies the research objective.
关 键 词:Gas-Turbine Ambient Temperature Humidity Combined Cycle EFFICIENCY Power Output HRSG
分 类 号:TG1[金属学及工艺—金属学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...