Pharmacokinetic-Pharmacodynamic modeling of the analgesic effect of bupredermTM, in mice  被引量:1

Pharmacokinetic-Pharmacodynamic modeling of the analgesic effect of bupredermTM, in mice

在线阅读下载全文

作  者:Min-Hyuk Yun Seung-Wei Jeong Chaul-Min Pai Sun-Ok Kim 

机构地区:[1]不详

出  处:《Health》2010年第8期824-831,共8页健康(英文)

摘  要:Purpose: BupredermTM-Buprenorphine transdermal delivery system (BTDS) was developed for the treatment of post-operative and chronic pains. This study examined the relationship between the plasma concentration of buprenorphine and its analgesic effect (tail flick test) in order to assess the usefulness of pharmacokinetic-pharmacodynamic (PK-PD) modeling in describing this relationship. Methods: After patch application, plasma concentrations of bu- prenorphine in mice were measured for 72 hours with a validated LC/MS/MS system, and the analgesic effects were assessed by tail flick test for the period of 24 hours. A modified two- compartment open model was used to explain the PK properties of BTDS, and the PD model was characterized by slow receptor binding. Results: The peak buprenorphine level in plasma was achieved at 1-24 h and the effective therapeutic drug concentration was maintained for 72 hours. BupredermTM induced prolongation of tail-flick latency in a dose and time dependent manner. Maximum analgesic effect was attained at 3-6 h and was maintained for 24 h after patch application. Counter-clockwise hysteresis between the plasma concentration and the analgesic efficacy of BTDS was observed after BupredermTM application, indicating there was a delay between plasma concentrations and the effect observed. From the developed PK-PD model, Kd values (0.69-0.82 nM) that were derived from the pharmacodynamic parameters (Kon and Koff) are similar to the reported values (Kd = 0.76 ± 0.14 nM). Good agreement between the predicted and observed values was noted for the rate of change in analgesic effect data (R2 = 0.822, 0.852 and 0.774 for 0.24, 0.8 and 2.4 mg/patch, respectively). Conclusions: The established PK- PD model successfully described the relationship between plasma concentration of buprenorphine and its analgesic efficacy measured by the tail flick test. Our model might be useful in estimation and prediction of onset, magnitude and time course of concentration and pharmacological effects of BTDS and willPurpose: BupredermTM-Buprenorphine transdermal delivery system (BTDS) was developed for the treatment of post-operative and chronic pains. This study examined the relationship between the plasma concentration of buprenorphine and its analgesic effect (tail flick test) in order to assess the usefulness of pharmacokinetic-pharmacodynamic (PK-PD) modeling in describing this relationship. Methods: After patch application, plasma concentrations of bu- prenorphine in mice were measured for 72 hours with a validated LC/MS/MS system, and the analgesic effects were assessed by tail flick test for the period of 24 hours. A modified two- compartment open model was used to explain the PK properties of BTDS, and the PD model was characterized by slow receptor binding. Results: The peak buprenorphine level in plasma was achieved at 1-24 h and the effective therapeutic drug concentration was maintained for 72 hours. BupredermTM induced prolongation of tail-flick latency in a dose and time dependent manner. Maximum analgesic effect was attained at 3-6 h and was maintained for 24 h after patch application. Counter-clockwise hysteresis between the plasma concentration and the analgesic efficacy of BTDS was observed after BupredermTM application, indicating there was a delay between plasma concentrations and the effect observed. From the developed PK-PD model, Kd values (0.69-0.82 nM) that were derived from the pharmacodynamic parameters (Kon and Koff) are similar to the reported values (Kd = 0.76 ± 0.14 nM). Good agreement between the predicted and observed values was noted for the rate of change in analgesic effect data (R2 = 0.822, 0.852 and 0.774 for 0.24, 0.8 and 2.4 mg/patch, respectively). Conclusions: The established PK- PD model successfully described the relationship between plasma concentration of buprenorphine and its analgesic efficacy measured by the tail flick test. Our model might be useful in estimation and prediction of onset, magnitude and time course of concentration and pharmacological effects of BTDS and will

关 键 词:Pharmacokinetic-Pharmacodynamic Modeling BupredermTM BUPRENORPHINE TRANSDERMAL System SLOW RECEPTOR-BINDING Model 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象