Development of simple HPLC/UV with a column-switching method for the determination of nicotine and cotinine in hair samples  

Development of simple HPLC/UV with a column-switching method for the determination of nicotine and cotinine in hair samples

在线阅读下载全文

作  者:Masayoshi Tsuji Yayoi Mori Hideyuki Kanda Teruna Ito Tomoo Hidaka Takeyasu Kakamu Tomohiro Kumagai Takehito Hayakawa Yoneatsu Osaki Tetsuhito Fukushima 

机构地区:[1]Department of Epidemiology and Public Health, School of Medicine, Yokohama City University, Yokohama, Japan [2]Department of Hygiene and Preventive Medicine, School of Medicine, Fukushima Medical University, Fukushima, Japan [3]Division of Environmental and Preventive Medicine, Department of Social Medicine, Faculty of Medicine, Tottori University, Yonago, Japan

出  处:《Health》2013年第4期687-694,共8页健康(英文)

摘  要:Nicotine and cotinine in hair are good biomarkers for assessing long-term exposure to smoking. However, analytical devices such as GC/MS are associated with high cost and are not widely used. HPLC/UV is used widely in laboratories, but is unsuitable for measurement of minor constituents, except when using the column-switching method. Thus, we aimed to establish a simple, inexpensive and sensitive method based on HPLC/UV with column switching for measuring nicotine and cotinine in hair. First, we compared the presence and absence of a column selection unit. We then measured amounts of nicotine and cotinine in hair samples collected from the general population, and compared both the corresponding levels and the detection limits with those in previous studies. Finally, initial and running costs of HPLC/UV were compared with other analytical methods. As one of the results, the areas of nicotine and cotinine measured by HPLC/UV with column-switching method were 12.9 and 16.9 times greater, respectively, than those without the column-switching method. The amount of nicotine and cotinine in hair was significantly correlated to number of cigarettes smoked per day (r = 0.228, p = 0.040). In addition, the HPLC/UV method showed similar sensitivity and detection limit (nicotine, 0.10 ng/mg;cotinine, 0.08 ng/mg) as reported in previous studies. The cost of the HPLC/UV method is lower than that of other analytical methods. We were able to establish a low-cost method with good sensitivity for measuring nicotine and cotinine in hair. The HPLC/UV with a column-switching method will be useful as a first step in screening surveys in order to better understand the effects of smoking exposure.Nicotine and cotinine in hair are good biomarkers for assessing long-term exposure to smoking. However, analytical devices such as GC/MS are associated with high cost and are not widely used. HPLC/UV is used widely in laboratories, but is unsuitable for measurement of minor constituents, except when using the column-switching method. Thus, we aimed to establish a simple, inexpensive and sensitive method based on HPLC/UV with column switching for measuring nicotine and cotinine in hair. First, we compared the presence and absence of a column selection unit. We then measured amounts of nicotine and cotinine in hair samples collected from the general population, and compared both the corresponding levels and the detection limits with those in previous studies. Finally, initial and running costs of HPLC/UV were compared with other analytical methods. As one of the results, the areas of nicotine and cotinine measured by HPLC/UV with column-switching method were 12.9 and 16.9 times greater, respectively, than those without the column-switching method. The amount of nicotine and cotinine in hair was significantly correlated to number of cigarettes smoked per day (r = 0.228, p = 0.040). In addition, the HPLC/UV method showed similar sensitivity and detection limit (nicotine, 0.10 ng/mg;cotinine, 0.08 ng/mg) as reported in previous studies. The cost of the HPLC/UV method is lower than that of other analytical methods. We were able to establish a low-cost method with good sensitivity for measuring nicotine and cotinine in hair. The HPLC/UV with a column-switching method will be useful as a first step in screening surveys in order to better understand the effects of smoking exposure.

关 键 词:HPLC/UV COLUMN-SWITCHING Method NICOTINE HAIR COTININE 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象