Availability of Heat Conduction for Environmental Control Method to Improving Thermal Environment and Preventing Oversensitivity to Cold and Air-Conditioning Disease on Female Office Workers  

Availability of Heat Conduction for Environmental Control Method to Improving Thermal Environment and Preventing Oversensitivity to Cold and Air-Conditioning Disease on Female Office Workers

在线阅读下载全文

作  者:Yoshihito Kurazumi Emi Kondo Kenta Fukagawa Reiko Hashimoto Yoshiaki Yamato Kunihito Tobita Tomonori Sakoi Tadahiro Tsuchikawa Tetsumi Horikoshi Yoshihito Kurazumi;Emi Kondo;Kenta Fukagawa;Reiko Hashimoto;Yoshiaki Yamato;Kunihito Tobita;Tomonori Sakoi;Tadahiro Tsuchikawa;Tetsumi Horikoshi(School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan;Department of Architecture, Ariake National College of Technology, Omuta, Japan;Department of Architecture, Kyushu Sangyo University, Fukuoka, Japan;Department of Architecture and Structural Engineering, Kure National College of Technology, Kure, Japan;School of Humanities and Social Sciences, Osaka Prefecture University, Sakai, Japan;Kansei Engineering Course, Shinshu University, Ueda, Japan;School of Human Science & Environment, University of Hyogo, Himeji, Japan;Department of Architecture, Aichi Sangyo University, Okazaki, Japan)

机构地区:[1]School of Life Studies, Sugiyama Jogakuen University, Nagoya, Japan [2]Department of Architecture, Ariake National College of Technology, Omuta, Japan [3]Department of Architecture, Kyushu Sangyo University, Fukuoka, Japan [4]Department of Architecture and Structural Engineering, Kure National College of Technology, Kure, Japan [5]School of Humanities and Social Sciences, Osaka Prefecture University, Sakai, Japan [6]Kansei Engineering Course, Shinshu University, Ueda, Japan [7]School of Human Science & Environment, University of Hyogo, Himeji, Japan [8]Department of Architecture, Aichi Sangyo University, Okazaki, Japan

出  处:《Health》2016年第6期583-604,共22页健康(英文)

摘  要:The purpose of this study is to demonstrate the effect localized heating of the feet has on physiological and psychological reactions of female in an air-conditioned environment in summer. In Japan, female office workers wear less clothing than their male counterparts. In an air-conditioned office space in summer, female conducts thermoregulation by putting on cardigans, etc. but this action does not greatly contribute to improving conditions for the legs and feet, the lower extremities of the body. The improvement of sensational and physiological temperature by localized warming of the body can contribute to a healthy working environment for female office workers, their safety, and a reduction in air conditioning’s energy expenditure. We used the indoor thermal environment evaluation index ETF to investigate the effect localized heating of the feet has on human physiological and psychological response in an air-conditioned environment in summer. The result of heating by means of heat conduction via the sole of the foot was expressed more strongly as a psychological effect than as a whole-body physiological effect. Heating by means of heat conduction via the sole of the foot was a thermal environment factor that compensates for a low temperature in whole-body thermal sensation and whole-body thermal comfort. The effect of heating due to heat conduction via the sole of the foot was expressed in the change in sole-of- the-foot skin temperature. Applying slight heat conduction by means of heating via the sole of the foot demonstrated the result of improved whole-body thermal sensation and whole-body thermal comfort.The purpose of this study is to demonstrate the effect localized heating of the feet has on physiological and psychological reactions of female in an air-conditioned environment in summer. In Japan, female office workers wear less clothing than their male counterparts. In an air-conditioned office space in summer, female conducts thermoregulation by putting on cardigans, etc. but this action does not greatly contribute to improving conditions for the legs and feet, the lower extremities of the body. The improvement of sensational and physiological temperature by localized warming of the body can contribute to a healthy working environment for female office workers, their safety, and a reduction in air conditioning’s energy expenditure. We used the indoor thermal environment evaluation index ETF to investigate the effect localized heating of the feet has on human physiological and psychological response in an air-conditioned environment in summer. The result of heating by means of heat conduction via the sole of the foot was expressed more strongly as a psychological effect than as a whole-body physiological effect. Heating by means of heat conduction via the sole of the foot was a thermal environment factor that compensates for a low temperature in whole-body thermal sensation and whole-body thermal comfort. The effect of heating due to heat conduction via the sole of the foot was expressed in the change in sole-of- the-foot skin temperature. Applying slight heat conduction by means of heating via the sole of the foot demonstrated the result of improved whole-body thermal sensation and whole-body thermal comfort.

关 键 词:FEMALE Office Worker Sensitivity to Cold Thermal Environment Thermal Sense 

分 类 号:TP3[自动化与计算机技术—计算机科学与技术]

 