作 者:Anna Öhman Anna Öhman(Friskispraktiken, Vastra Hmangatan 7A, Gothenburg, Sweden)
机构地区:[1]Friskispraktiken, Vastra Hmangatan 7A, Gothenburg, Sweden
出 处:《Health》2016年第12期1258-1265,共8页健康(英文)
摘 要:Objective: The aim of the study was to determine the intra- and inter-reliability for measuring infants with plagiocephaly and brachycephaly with a craniometer when using a marked headband as landmarks. Subjects: Six physiotherapists and eight infants participated in the study. Methods: The physiotherapists measured all infants twice;each infant was measured with the same headband and craniometer. The physiotherapists were blinded to measurements carried out by their colleagues. The infants with their parents changed places in the room to minimize the possibility that the physiotherapists would remember their first measurements of any infant. Results: There was a high intra- and inter-reliability, for intra-reliability ICC 0.96 to 0.99 and for inter-reliability ICC 0.98. Conclusion: It is possible to achieve a high intra- and inter-reliability when using a headband and craniometer when measuring cranial vault asymmetry for plagiocephaly and cephalic ratio for brachycephaly.Objective: The aim of the study was to determine the intra- and inter-reliability for measuring infants with plagiocephaly and brachycephaly with a craniometer when using a marked headband as landmarks. Subjects: Six physiotherapists and eight infants participated in the study. Methods: The physiotherapists measured all infants twice;each infant was measured with the same headband and craniometer. The physiotherapists were blinded to measurements carried out by their colleagues. The infants with their parents changed places in the room to minimize the possibility that the physiotherapists would remember their first measurements of any infant. Results: There was a high intra- and inter-reliability, for intra-reliability ICC 0.96 to 0.99 and for inter-reliability ICC 0.98. Conclusion: It is possible to achieve a high intra- and inter-reliability when using a headband and craniometer when measuring cranial vault asymmetry for plagiocephaly and cephalic ratio for brachycephaly.
关 键 词:PLAGIOCEPHALY Brachycephaly Measurement Craniometer Headband INFANT
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.143.211.215